Plan your installation Step One Draw your total room area including all fixed furniture such as kitchen units, toilets and sink areas. Mark your drawing with all relevant dimensions. Step Two Decide on your heating requirements, for example 200watts per sqm is ideal for conservatories and sunrooms. If you require any further advice or information on heating loads please do not hesitate to contact our help line on 01299 266 536 Step Three Calculate the total square area of the room. Multiply the square area of the room by the heating load required. For example if the square area of the room equalled 14 sqm and the heating load required was 200watts per square meter the total heating load would be 2800watts. Step Four Select the nearest eCable or kit for the calculated total load. For example total load required 2800watts you would select a eCable20-132 or eCablekit14-14.
It is important when calculating your eCable spacing to accurately draw your room area as this will help to save time and ensure a smooth installation. |
|
|